| LEDS 1 2 3 4 |
Error Description |
| 0 0 0 1 |
No slave on line, master will not IPL until at least
one device is powered on. |
| 0 0 1 0 |
No disk in floppy drive and IPL from floppy was
selected. |
| 0 0 1 1 |
SMD drive not powered on/ not on-line |
| 0 1 0 0 |
Hawk drive not powered on/ not on-line |
| 0 1 0 1 |
Run-time error, press Reset button |
| 1 0 0 0 |
CPU board error (7501 or 7684) |
| 1 0 0 1 |
Data Link board (7503 or 7504) |
| 1 0 1 0 |
Floppy/Hawk board (7502) |
| 1 1 0 0 |
SMD (7505/7506) or Winchester board (7950/7653) |
| 1 1 1 0 |
Expanded memory board (7685) |
| 1 1 0 1 |
Software error (often damaged system volume) |
| 1 1 1 1 |
Parity error (7501) can be caused by failed voltage
regulator also. |
| Hex Code |
DL7-DL4 |
DL3-DL0 |
Description |
| 10 |
0001 |
0000 |
Data Bus Error |
| 20 |
0010 |
0000 |
MPE Bit does not flag parity errors |
| 30 |
0011 |
0000 |
NMI does not generate from parity error |
| 40 |
0100 |
0000 |
Main memory parity error |
| 50 |
0101 |
0000 |
Memory error, 1st read of read/write/read sequence |
| 65 |
0110 |
0101 |
CTC Time Out occured |
| 75 |
0111 |
0101 |
CTC priority error |
| 80 |
1000 |
0000 |
Memory error, 2nd read of read/write/read sequence |
| 94 |
1001 |
0100 |
Incorrect interrupt vector generated |
| a4 |
1010 |
0100 |
No interrupts generated |
| b4 |
1011 |
0100 |
Incorrect number of interrupts generated |
| c0 |
1100 |
0000 |
Illegal PROM address error. |
| 16 |
0001 |
0110 |
R/W Control registers error |
| 36 |
0011 |
0110 |
Cannot select a slave |
| 46 |
0100 |
0110 |
Cannot IPL a slave |
| 56 |
0101 |
0110 |
1-byte slave read error |
| 76 |
0111 |
0110 |
Data link time out doing block transfer |
| 86 |
1000 |
0110 |
No data link busy interrupt generated |
| 96 |
1001 |
0110 |
Data buffer parity error doing block transfer |
| a6 |
1010 |
0110 |
Incorrect data found after block transfer |
| 17 |
0001 |
0111 |
R/W Control registers error |
| 27 |
0010 |
0111 |
IPL from floppy status error |
| 47 |
0100 |
0111 |
Cannot find track 0 on floppy |
| 77 |
0111 |
0111 |
No sector pulse interrupt |
| 97 |
1001 |
0111 |
Sector counter never indicates sector |
| 18 |
0001 |
1000 |
R/W Control registers error (Hawk) |
| 38 |
0011 |
1000 |
Drive select register error |
| 48 |
0100 |
1000 |
Hawk drive does not restore |
| 58 |
0100 |
1000 |
Restore takes greater then 500ms |
| 68 |
0110 |
1000 |
No interrupt on Seek Complete |
| 78 |
0111 |
1000 |
No sector pulse interrupt |
| 88 |
1000 |
1000 |
IPL from Hawk status error |
| 98 |
1001 |
1000 |
Sector counter never indicates sector 0 |
| 19 |
0001 |
1001 |
R/W Control registers error (SMD) |
| 29 |
0010 |
1001 |
Seek operation failed to cause interrupt |
| 39 |
0011 |
1001 |
Seek operation returned bad status |
| 49 |
0100 |
1001 |
Incorrect interrupt vector on seek |
| 59 |
0101 |
1001 |
Read operation failed to cause interrupt |
| 69 |
0110 |
1001 |
Read IPL sector returned bad status (Includes ECC
error) |
| 1E |
0001 |
1110 |
R/W Control registers error (Winchester) |
| 2E |
0010 |
1110 |
Drive does not become ready |
| 3E |
0011 |
1110 |
No seek interrupt on RTZ |
| 4E |
0100 |
1110 |
Track 0 not set after RTZ |
| 5E |
0101 |
1110 |
Timeout on IPL read |
| 6E |
0110 |
1110 |
Status error on IPL read |
| 7E |
0111 |
1110 |
Cannot find sector 0 |
| 8E |
1000 |
1110 |
Head/Select forced error |
| 9E |
1001 |
1110 |
No seek interrupt on seek |